LEONI Fiber Connect - I-VHH 2x1 (Breakeout cable - flat)
Description:
Light, thin and rugged indoor cable for use as a patch cable in distribution systems, as connection cable for terminals as well as for workstation cabling. For direct connector assembly.
Order no: 84 . . . .
Standardisation:IEC 60794-2
Composition:
Cable core - Two single-fiber cables (TB or STB) arranged in parallel beside each other with non-metallic strain relief elements (aramid) and a halogen-free, flame-retardant subcable jacket (Ø see table)
Cable jacket - Halogen-free, flame-retardant material
Colour of jacket - orange for multimode, yellow for singlemode
Construction:
|
|
Thermal properties:
- Transport/storage: – 25 °C to + 70 °C
- Installation: – 5 °C to + 50 °C
- Operating temperature: – 10 °C to + 70 °C
Fire performance:
- Flame retardancy: IEC 60332-1-2 and IEC 60332-3-22 Cat. A
- Smoke density: IEC 61034
- Absence of halogen: IEC 60754-1
- Acidity of combustion gases: IEC 60754-2
Mechanical properties:
Min. bending radius: | static: 35 mm | |
dynamic: 65 mm |
Single element |
Cable outer dimensions |
Type | Weight | max. pull force long-term |
max. - crush resistance long-term |
Fire load | Order no. TB |
Order no. STB |
mm | mm | kg/km | N | N/dm | MJ/m | |||
1,7 | 2.8 × 4.5 | I-V(ZN)HH 2×1… | 16,5 | 400 | 400 | 0,58 | 84950881 ■ TB600L | 84950887 ■ STB600 |
1,8 | 2.9 × 4.7 | I-V(ZN)HH 2X1… | 17,5 | 400 | 400 | 0,60 | 84950882 ■ TB600L | 84950886 ■ STB600 |
2,0 | 3.1 × 5.2 | I-V(ZN)HH 2X1… | 19,0 | 600 | 400 | 0,63 | 84070■■■■ TB900L | 84070■■■■ STB900 |
2,1 | 3.1 × 5.2 | I-V(ZN)HH 2X1… | 19,0 | 600 | 400 | 0,63 | 84017■■■■ TB900L | 84017■■■■ STB900 |
2,5 | 3.7 × 6.2 | I-V(ZN)HH 2X1…* | 26,0 | 600 | 600 | 0,65 | 8401101L ■ TB900L | 84011011 ■ STB900 |
2,8 | 4.0 × 6.8 | I-V(ZN)HH 2X1… | 32,0 | 600 | 600 | 0,83 | 8401201L ■ TB900L | 84012011 ■ STB900 |